The L_DCO_DriveCommunication library
Function blocks
104
Lenze · Commissioning of Lenze drives · 1.3 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.3 Function blocks
12.3.1 L_DCO_AXIS_REF_BASE
This FB provides the basic communication information of the Logic axis.
Every Logic axis implemented in the control configuration is an extended instance of
L_DCO_AXIS_REF_BASE. A manual instancing of this function block is not required.
The function block L_DCO_AXIS_REF_BASE has routines that serve as drivers.
Input variables
Outputs
Function library: L_DCO_DriveCommunication
Runtime software licence: LPC 1x00 MPC 1x00 MPC 2xx0 MPC 3x00
L_DCO_AXIS_REF_BASE
UDINT udiTimeOut uiDeviceID UINT
USINT usiChannel uiNetID UINT
ARRAY[1.. 5] OF
L_DCO_SdoData
aSDOReadData xCommunicationOK BOOL
ARRAY[1.. 5] OF
L_DCO_SdoData
aSDOWriteData eCommunicationState L_DCO_CommState
AxisName STRING
Identifier Data type Initialisation Information/possible settings
udiTimeOut UDINT 10000 Timeout period for SDO communication
usiChannel USINT 1 SDO channel to be used
aSdoReadData ARRAY[1.. 5] OF
L_DCO_SdoData
0 Exchange for SDO communication
(internal use)
aSdoWriteData ARRAY[1..5] OF
L_DCO_SdoData
0
Identifier Data type Initial value Information/possible settings
uiDeviceId UINT 0 Station/node address at the used bus system
uiNetId UINT 0 Network/master instance number of the used bus
system.
xCommunicationOK BOOL FALSE Status of bus communication
FALSE No bus communication active
TRUE Bus communication available
eCommunicationState L_DCO_Com
mState
0Bus state
AxisName STRING - Instance name