L-force | PLC Designer
We Write a Little Program
86 DMS 3.2 EN 02/2011 TD29
5.1.15 Actions and transition conditions
In the action of the step Init the variables are initialized, the STATUS of
TRAFFICSIGNAL1 should be 1 (green). The state of TRAFFICSIGNAL2 should be 3 (red).
The action Init then looks like in the following image:
Action Init
Switch1 changes the sate of TRAFFICSIGNAL1 to 2 (yellow), and that of
TRAFFICSIGNAL2 to 4 (yellow-red). In addition, a time delay of 2000 milliseconds is set.
The action is now as follows:
Action Switch1
With Green2 TRAFFICSIGNAL1 is red (STATUS:=3), TRAFFICSIGNAL2 green (STATUS:=1),
and the delay time is 5000 milliseconds.
Action Green2