Compiler Errors and Warnings
584 DMS 3.2 EN 02/2011 TD29
3254
"Call to external library function could not be resolved."
The target is currently not supported.
3255
"Pointers are not supported for 8 bit controllers."
Avoid using pointers in your program to get it running on the 8 bit system.
3260
"Function ‚<name>’ has too many arguments: Increase the size of the argument stack
in the target settings."
If possible, modify the size of the stack in dialog ‚Target Platform’ in the Target
Settings (Default: 40). If the setting is not editable in »PLC Designer«, please contact
the PLC manufacturer.
3400
"An error occured during import of Access variables"
The .exp file contains an incorrect access variables section.
3401
"An error occured during import of variable configuration"
The .exp file contains an incorrect configuration variables section.
3402
"An error occured during import of global variables"
The .exp file contains an incorrect global variables section.
3403
"Could not import <name>"
The section for object <name> in the .exp file is not correct.
3404
"An error occured during import of task configuration"
The section for the task configuration the .exp file is not correct.