DMS 3.2 EN 02/2011 TD29 187
6.4.9 'Project' 'Object Convert'
This command can only be used with POUs. You can convert POUs from the languages
SFC, ST, FBD, LD, and IL into one of the three languages IL, FBD, and LD.
For this the project must be compiled. Choose the language into which you want to
convert and give the POU a new name. Remember that the name of the POU may not
have already been used. Then press OK, and the new POU is added to your POU list.
The type of processing that occurs during conversion corresponds to that which
applies to compilation.
Stop!
Actions cannot be converted.
Dialog box for converting a POU
Regard the following possibility: A POU which has been created in the FBD-Editor, can
- using the command 'Extras' 'View' be displayed and edited in the KOP-Editor as well
without any conversion.