Lenze 9400 Manuel d'utilisateur Page 648

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 954
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 647
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
648
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Motor: Calculated motor impedance unrealistic [0x007b0001]
Motor: Calculated mutual inductance unrealistic [0x007b0002]
Motor data are inconsistent [0x007b0003]
Motor: Phase resistance too high [0x007b0004]
Motor: Device current too low for rated magnetisation [0x007b0006]
Module ID (decimal) Error ID (decimal)
123: Motor control 1
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Module ID (decimal) Error ID (decimal)
123: Motor control 2
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Module ID (decimal) Error ID (decimal)
123: Motor control 3
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Module ID (decimal) Error ID (decimal)
123: Motor control 4
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Faulty motor parameterisation. Check motor parameters.
Module ID (decimal) Error ID (decimal)
123: Motor control 6
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Controller current is too low for rated magnetisation, i.e.
the controller cannot energise the motor sufficiently.
Check drive dimensioning.
Vue de la page 647
1 2 ... 643 644 645 646 647 648 649 650 651 652 653 ... 953 954

Commentaires sur ces manuels

Pas de commentaire