12 Oscilloscope
12.4 Operation
586
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.4.4 Starting recording
Click Start to start recording.
To obtain a maximum sampling rate when recording the variable values, the data are first stored in
the measured data memory of the controller and then transferred as a data record to the PC. The
current recording status is shown in the status bar.
Edge If the trigger source is a channel or a variable, you can choose between the following trigger
modes:
Positive edge For triggering on a BOOL variable:
• Trigger activation requires a FALSE-TRUE transition.
For triggering on a different variable:
• For trigger activation, the selected trigger value must be exceeded.
Negative edge For triggering on a BOOL variable:
• Trigger activation requires a TRUE-FALSE transition.
For triggering on a different variable:
• For trigger activation, the selected trigger value must be fallen below.
Change For triggering on a BOOL variable:
• Trigger activation requires a state change.
For triggering on a different variable:
• For trigger activation, the current value must be different than the last value.
Setting Function
Note!
Starting the recording mode is only possible when an online connection has been
established to the controller.