11 Basic drive functions
11.6 Homing
428
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 0: pos. direction - via home mark - to TP
Procedure:
1. Movement in positive direction with profile data set 1.
2. Positive edge at HM_bHomingMark activates profile data set 2 for the further reference search.
3. Negative edge at HM_bHomingMark enables home position detection.
4. The following positive edge of the encoder zero pulse/touch probe sensor sets the reference.
5. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Note!
Drive behaviour after setting the reference
From software version V4.0 onwards, C02641
serves to parameterise the drive
behaviour after setting the home position.
Drive behaviour after setting the home position
( 423)
In the Lenze setting (C02641
= "0"), the drive traverses to the absolute target position set
in C02643
similarly to the behaviour known from the previous versions.
Touch probe/zero pulse
 Reference switch