5 Motor interface
5.7 V/f control (VFCplus)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Internal variables of the motor control (oscilloscope signals)
The red numbers in brackets listed in the signal flow stand for internal variables of the motor
control, which you can record by means of the Oscilloscope
for purposes of diagnostics and
documentation.
( 579)
No. Variable of the motor control Meaning
(1) Speed.dnSpeedSetpoint Speed setpoint
(2) Current.Current.dnActualMotorCurrent Actual motor current
(3) Current.dnActualQuadratureCurrent Actual Q current
(4) Speed.dnActualMotorSpeed Current motor speed
(6) Frequency.dnActualRotatingFieldFrequency Actual field frequency
(7) Voltage.dnOutputQuadratureVoltage Q voltage
(8) Voltage.dnOutputDirectCurrentCtrl D voltage
(9) Voltage.dnActualMotorVoltage Current motor voltage