Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 627
13 Diagnostics & fault analysis
13.7 Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Memory module is defect or missing [0x0068000c]
Safety module is defect or missing [0x0068000d]
Control card incompatible [0x0068000e]
Power section incompatible [0x0068000f]
MXI1: Wrong module [0x00680010]
Module ID (decimal) Error ID (decimal)
104: Module identification 12
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Operating system could not identify the memory
module.
• Use a different memory module.
• Please contact Lenze.
Module ID (decimal) Error ID (decimal)
104: Module identification 13
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Operating system could not identify the safety module. • Use a different safety module.
• Please contact Lenze.
Module ID (decimal) Error ID (decimal)
104: Module identification 14
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The control card is not supported by the operating
system.
Consultation with Lenze required.
Module ID (decimal) Error ID (decimal)
104: Module identification 15
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The power section is not supported by the operating
system.
Consultation with Lenze required.
Module ID (decimal) Error ID (decimal)
104: Module identification 16
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The extension module in module slot MXI1 is not
supported by the operating system.
• Use a different module.
• Please contact Lenze.