Lenze 9400 Manuel d'utilisateur Page 272

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 954
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 271
7Braking operation
7.2 Monitoring
272
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.2.4 DC bus overvoltage
If, due to a too high braking energy, the DC-bus voltage exceeds the overvoltage threshold which
results from the mains voltage setting in C00173
, the "Overvoltage in the DC bus" error message is
output and the response set in C00600
is activated (default setting: "Trouble").
Note!
For hoist applications, the "Fault" response should be selected in C00600 (in combination
with an emergency stop via mechanical brakes).