Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 811
14 Parameter reference
14.2 Parameter list | C00692
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00692
C00693
C00694
C00695
C00696
C00697
Parameter | Name:
C00692 | Speed setpoint [%]
Data type: INTEGER_32
Index: 23883
d
= 5D4B
h
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00693 | Actual speed [%]
Data type: INTEGER_32
Index: 23882
d
= 5D4A
h
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00694 | Speed controller output
Data type: INTEGER_32
Index: 23881
d
= 5D49
h
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00695 | Total torque setpoint
Data type: INTEGER_32
Index: 23880
d
= 5D48
h
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00696 | Torque setpoint [%]
Data type: INTEGER_32
Index: 23879
d
= 5D47
h
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100
Parameter | Name:
C00697 | Filtered torque setpoint
Data type: INTEGER_32
Index: 23878
d
= 5D46
h
Display range (min. value | unit | max. value)
-200.00 % 200.00
Read access Write access CINH PLC STOP No transfer Scaling factor: 100