Lenze 9400 Manuel d'utilisateur Page 48

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 954
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 47
4 Drive interface
4.2 Device commands
48
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2.5 Save selected application
After mains switching the controller always loads the preset start application from the memory
module, even if a different application has been active before.
With the device command C00002
= "7: Save selected application" the active application can be
defined as start application.
[4-15] "Save selected application" function
When this device command is executed, the parameter set is also saved automatically.
The number of the currently active application is displayed in C00007
.
Possible status displays for this device command
Related device commands
Activate application
( 47)
Start application
( 53)
Stop application
( 54)
* In this example, the active application 2 is defined as start application
PS
9400
RAM
Firmware Application 2*
PS
Application 3
Memory module MM
Application 1
Application 2*
PS
Status (C00003) Meaning
492802 Device command in process
458752 Device command executed successfully
458753 General fault
Vue de la page 47