Lenze EtherCAT control technology Manuel d'utilisateur Page 64

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 204
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 63
Control technology | EtherCAT communication manual
Commissioning of the system
Detailed commissioning steps
64 L DMS 3.1 EN 01/2011 TD17
Not all parameters required for operating a Motion drive acan be set automatically via the
control.
Set the following parameters for the Servo Drives 9400 HighLine CiA402 manually via the
»Engineer« or the »Global Drive Control«:
Homing mode (C02640, to be set machine-dependent)
Touch-probe interface (to be set machine-dependent)
Control of a holding brake (0x60FB/2 | Brake control)
Depending on the setting of this parameter, the holding brake is applied for a short
time after the conclusion of the home position path. In order to avoid this, set bit 2
in this parameter (disable stop => does not apply the brake in standstill).