Control technology | EtherCAT communication manual
Parameter reference
Interface parameters of the MC-ETC communication card in slot 2
196 L DMS 3.1 EN 01/2011 TD17
C1596/27
C1596/28
C1596/29
C1596/30
C1596/31
Parameter | Name:
C1596/27 | ECAT RX Error Counter Port 3
Data type: UNSIGNED_16
Index: 22979.27
d
=
0x59C3.0x1B
h
Number of errors that have occurred during data reception via port 3.
Display range (min. value | unit | max. value)
0 65535
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1596/28 | Forwarded ECAT RX Error Counter Port 0
Data type: UNSIGNED_8
Index: 22979.28
d
=
0x59C3.0x1C
h
Number of errors which have occurred at upstream slave nodes (referred to the position of the current slave in the
bus topology) during data reception via port 0.
Display range (min. value | unit | max. value)
0 255
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1596/29 | Forwarded ECAT RX Error Counter Port 1
Data type: UNSIGNED_8
Index: 22979.29
d
=
0x59C3.0x1D
h
Number of errors which have occurred at upstream slave nodes (referred to the position of the current slave in the
bus topology) during data reception via port 1.
Display range (min. value | unit | max. value)
0 255
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1596/30 | Forwarded ECAT RX Error Counter Port 2
Data type: UNSIGNED_8
Index: 22979.30
d
=
0x59C3.0x1E
h
Number of errors which have occurred at upstream slave nodes (referred to the position of the current slave in the
bus topology) during data reception via port 2.
Display range (min. value | unit | max. value)
0 255
; Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C1596/31 | Forwarded ECAT RX Error Counter Port 3
Data type: UNSIGNED_8
Index: 22979.31
d
=
0x59C3.0x1F
h
Number of errors which have occurred at upstream slave nodes (referred to the position of the current slave in the
bus topology) during data reception via port 3.
Display range (min. value | unit | max. value)
0 255
; Read access Write access CINH PLC STOP No transfer