Lenze · ApplicationTemplate · 1.3 EN - 04/2013 41
Working with the ApplicationTemplate
Mapping the actual machine structure in the »PLC Designer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2. Add an EtherCAT slave below the EtherCAT Master: Right-click the EtherCAT Master
Add device:
Select the desired device from the selection list .
The »PLC Designer« provides a "fieldbus scan" during which the devices connected to the
fieldbus are automatically detected.
Further information is provided in the "Controller-based Automation EtherCAT" section of
the online help for the »PLC Designer« and in the Controller-based Automation EtherCAT
communication manual (KHB).
Repeat the Add device until all slaves connected to the fieldbus are implemented in the
device view.