Lenze · ApplicationTemplate · 1.3 EN - 04/2013 125
The L_EATP_ApplicationTemplate library
1_POUs - Program Organization Units
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.2.10 L_EATP_ModulRelations
This FB provides an overview of how the machine modules are linked.
This FB can for instance be used to retrace whether the interconnection of structures and the
assignment of the module address have worked.
Inputs
Outputs
Function library: L_EATP_ApplicationTemplate
Runtime software licence: LPC 1x00 MPC 1x00
MPC 2x00
MPC 2x10
MPC 2x20
MPC 2x30
MPC 3x00 ; None
L_EATP_ModuleRelations
BOOL Enable numberOfModules INT
relationsAsString BOOL
Success BOOL
Identifier/data type Information/possible settings
Enable
BOOL
In the case of a positive edge, the module analysis will start.
Identifier/data type Information/possible settings
numberOfModules
INT
Number of machine modules identified
relationAsString
ARRAY [1...30] OF STRING
For every master-slave relation identified, there is an entry with the corresponding
master and slave in the array.
The entry has the following structure: <master instance name>[<master module
address>] -> <slave instance name>[<slave module address>]
Example: MachineModule[1] -> InFeed[3]
Success
BOOL
Supplies a response stating whether the analysis has been correct.
TRUE Analysis executed correctly.
FALSE An error has occurred during the analysis