L Firmware 1.37 - 09/2006 63
9400 HighLine | Parameter setting & configuration
Drive interface
System block "LS_DriveInterface"
4.7.1 Status signals
The following representation shows which status signals of the system block
LS_DriveInterface are set to TRUE in different typical cases:
Case 1:
Application has been transmitted to the controller.
No mains voltage available (LU fault).
Controller is inhibited (via RFR terminal).
Case 2:
Mains voltage has been connected.
Case 3:
Controller inhibit has been deactivated.
Case 4:
Fault is active.
Case 5:
Quick stop by trouble is active
Status Status signal (output)
Ready for operation
z z DI_bReady
Fault is active
z z DI_bFailActive
Pulse inhibit is active
z z z DI_bImpActive
Controller inhibit is active
z z z DI_bCinhActive
Warning is active
DI_bWarningActive
Undervoltage detected
z DI_bUVDetected
Overvoltage detected
DI_bOVDetected
Mains supply is Ok
z z z z DI_bMainSupplyOk
Ready to switch on
DI_bReadyToSwitchOn
Operation enabled
z DI_bOperationEnabled