9400 HighLine | Parameter setting & configuration
Basic drive functions
Brake control | Parameter setting
220 Firmware 1.37 - 09/2006 L
r To ensure the correct direction at start-up, the speed controller is loaded with the
following starting torques:
r This results in the following behaviour depending on load and direction:
Feedforward control with memorised torque
[9-16] Feedforward control with parameterised starting torque
Lifting Lowering
Starting torque: C02586
= 50 Nm C02587 = 10 Nm
Lifting Lowering
Behaviour at max. load: Optimum behaviour Start-up a bit fast, but correct direction
(non-critical).
Behaviour without load: Start-up a bit fast, but correct direction
(non-critical).
Optimum behaviour
p C02588
: Waiting torque source
r When C02588 = 1, the starting torque
is the setpoint which has been
automatically memorised during the
last closing process (falling below the
speed threshold set in C02581
).
1
0
1
0
C02588 = 1
S&H
CTRL
Speed controller
Note!
The higher the threshold for brake activation set in C02581, the higher is the
dynamic part in the marked torque (e.g. the speed-dependent friction torque).
In the special case that the load changes when the brake is closed, a correction
value, which is added to the marked torque, can be defined for the torque
precontrol via the input BRK_dnTorqueAdd_n.