Electrical installation
HighLine C control terminals
Motor holding brake connection
6
236
EDS84ASC552 EN 9.1
6.8.4 Motor holding brake connection
Note!
If terminal X107 is used for connecting a motor holding brake, at least one
basic insulation to the motor or mains potential has to be provided, so that the
protective separation of the control terminals is not limited.
X107
24B
X107
GBBD1
BD2
"
DC 24 V
(+19.2...+28.8 V)
M
8400HLC037 8400HLC045
Labelling Description
24B Connection for external 24 V supply
voltage of the motor holding brake
Observe correct polarity!
DC 19.2 ... 28.8 V, IEC 61131-2
SELV/PELV
Example circuit 258
GB GND connection for external supply
BD1 Pos. connection of the motor
holding brake (Lenze: WH)
BD2 Neg. connection of the motor
holding brake (Lenze: BN)
Terminal data
Conductor cross-section Tightening torque
[mm
2
] [AWG] [Nm] [lb-in]
Flexible
0.2 ... 1.5
24 ... 16 - - -
With wire end ferrule