Product description
Overview of standard devices
3
21
EDS84ASC552 EN 9.1
Connection Information
Pos. Description 230 V 400 V
X80 Terminal strip for the integrated safety unit 270
X100 Mains/DC-bus voltage (for 400 V devices)
– For devices in device size 6 (18.5 ... 22 kW) the terminal strip
is not pluggable.
182 192
X101 Relay output 219
X105 Motor/external brake resistor
– For devices in device size 6 (18.5 ... 22 kW) the terminal strip
is not pluggable.
186 196
X106 Motor temperature monitoring 185 197
IT Contact screw for interference suppression (on the supply
side/on the motor side)
183 194
MCI Slot for communication module (Module Communication
Interface)
294
Sticker with w arning -