Lenze PLC Designer V2.x Manuel d'utilisateur Page 326

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 336
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 325
PLC Designer V2.x| Lenze Application Samples
The L_SSC_Scaling.lib library
L_SSC_SetAxisData - machine parameters
326 L 1.3 EN - 07/2012
20.15 L_SSC_SetAxisData - machine parameters
With this FB the machine parameters of a higher-level drive can be mapped. The FB
conditions the machine parameters, which you specify in the physical units of the machine
via parameters, for the internal representation.
At the output scAxisData the FB provides a pointer to the data structure with the
machine parameters conditioned.
In order to pass the machine parameters to another FB which requires these data for
internal calculations, the output scAxisData is to be connected to the input with the
same name of the corresponding FB.
Inputs
Identifier/data type Information/possible settings
rFeedConstant
REAL
Feed constant
Initialisation: 360.0 units
rCycleLength
REAL
Cycle
Initialisation: 360.0 units
dwGearNumerator
DWORD
Gearbox factor numerator
Initialisation: 1
dwGearDenominator
DWORD
Gearbox factor denominator
Initialisation: 1
rMaxSpeed
REAL
Reference speed
sAxisName
STRING(16)
Axis name
eMode SSC_Mode :=
MODULO
Traversing range
0 unlimited
1 limited
2 modulo (Lenze setting)
dwResolution
DINT
Resolution of one revolution