1.3 EN - 07/2012 L 269
PLC Designer V2.x| Lenze Application Samples
The L_S8V_Drive82Vector.lib library
L_S8V_ActuatorSpeed - actuation of the 8200 vector controller
14.1.2 Status of the controller
Further information on the controller can be found in the following
documentation:
System manual (SHB) 8200 vector - Global Drive
–Section Function library
Code table | Controller status word 1 (parameter
channel)
Identifier/data type Control bits in the controller
Bit Identifier Meaning
xFreeBit00 0 Not assigned
xImp 1DCTRL1-IMP Pulse inhibit
xQSPActive 2 Mapping of C0417/3 Quick stop status
xDriveError
BOOL
3 Mapping of C0417/4 Controller in error status
TRUE: Error active
xFreeBit04 4 Not assigned
xFreeBit05 5 Not assigned
xSpeedEqZero 6 DCTRL1-NOUT=0 Activate quick stop
xDriveEnabled
BOOL
7DCTRL1-CINH Controller is active (controller inhibit is
deactivated)
xFreeBit08 8 Not assigned
xFreeBit09 9 Not assigned
xFreeBit10 10 Not assigned
xFreeBit11 11 Not assigned
xWarning 12 DCTRL1-OH-WARN TRUE: Warning active
xFreeBit13 13 Not assigned
xCcw 14 Mapping of C0417/15 Set reversal of rotation direction
xDriveReady
BOOL
15 Mapping of C0417/16 Controller is ready for operation
rNact
REAL
Actual speed value