Working with the sample projects
9300 - "LAS_40_INTF_Can_93_EP" sample project
8.8.2 Short overview of the functions
8.8.2.1 Commissioning
How to commission the 9300:
1. Connect the 9300 servo inverter and the Engineering PC to the PC system bus
adapter (EMF2177).
2. Switch on voltage supply.
Mode Description
Automatic In the automatic mode a sequence runs over an infinite loop.
Selection:
When the drive is referenced...
1.Travel to Position 1,
2.Travel to Position 2,
3.Start at (1.) again.
Manual In manual mode, the controller can be actuated by setting the individual
control bits manually (Jog1, Jog2, QSP, ErrorReset...). Like this, the controller
can be actuated in manual mode, for instance for cleaning or changing the
tools.
Service The service mode serves to adjust the controller.
Selection:
• Travel in positive direction for one second,
•Stop for one second,
• Travel in negative direction for one second.
Homing In the homing mode the drive is referenced.
• Either the home position is set directly, or a homing is started.
Read the mounting instructions supplied with the controller first before you start
working!
The mounting instructions contain safety instructions which must be observed!