EDS94TA10040xxxx EN 1.1 - 10/2008 L 59
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
4.14.8 ElectricalShaftData
Is an instance of Function
L_SdSetAxisData Mapping of the machine parameters of the higher-level drive (master shaft).
Master axis (master shaft)
(C 26)
Parameter Possible settings Information
C03930 1 2147483647 Gearbox ratio - numerator
•Initialisation: 1
C03931 1 2147483647 Gearbox ratio - denominator
•Initialisation: 1
C03932 0.0001 Unit/incr. 214748.3647 Feed constant
Initialisation: 360 units/incr.
C03933 Path unit
0 User-defined Selection in C03934
1Inc
2 μm
3mm
4m
5inch
6yard
Lenze setting
C03934 Character string, max. 8 characters User-defined path unit
C03935 At present, the unit of the time base is
permanently set to "s" and cannot be
changed!
Time unit
C03938 0.0000 unit 214748.3647 Cycle
Initialisation: 360 unit
C03939 10 Bit 24 Resolution of encoder revolution
Initialisation: 16 bits
C03941 -214748.3647 unit/t 214748.3647 Reference speed
•Initialisation:
36000.0000 units/t
C03942 Traversing range
0Unlimited
1 Limited
2Modulo Lenze setting
C03948 -2147483.647 2147483.647 Resulting gearbox factor
•Read only
C03949 -214748.3647 Incr. 214748.3647 Resolution - application unit
•Read only