Lenze E94AxHE Technology Application Synchronism Manuel d'utilisateur Page 40

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 80
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 39
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
40 L EDS94TA10040xxxx EN 1.1 - 10/2008
TP profile parameters
r Parameter setting: Tab Application parameters dialog level Overview Synchronism
TP profile parameters
r Configuration: Tab FB editor FB MarkSynchronizationTool
TP interface
r Parameter setting: Tab Application parameters dialog level Overview Synchronism
TP interface
Parameter Lenze setting
Value Unit
C03855 Positioning mode 0
C03856 Deactivation mode 0
C03858/1 Positive speed 1000.0000 unit/t
C03858/2 Negative speed 1000.0000 unit/t
C03861/1 Acceleration ramp 1.000 s
C03861/2 Deceleration ramp 1.000 s
C03861/3 Stop ramp 1.000 s
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Activate tool TP correction C03058/23
Parameter Lenze setting
Value Unit
C02810/2 Signal delay TP2 0 μs
C03031 Edge evaluation of positive edge TRUE
C03032 Edge evaluation of negative edge FALSE