EDS94TA10040xxxx EN 1.1 - 10/2008 L 37
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
4.5.4 Master value trimming
[4-8] "Master value trimming" function in the signal flow (schematic diagram)
This function serves to adjust the master value.
r Parameter setting: Tab Application parameters dialog level Overview Synchronism
Master value trimming
r Configuration: Tab FB editor FB Trimming
n Master value with clutch
o Master value with trimming

M
v
Slave
Real master/
Virtual master
C03006 = 0
v
t
Dj
Dj Dj
TP TP
Parameter Lenze setting
Value Unit
C03674 Master value with clutch - unit
C03026 Activate trimming Deactivated
C03676 Adjustable range 0.0000 unit/t
C03685 Positioning mode 0
C03686 Deactivation mode 1
C03688/1 Positive speed 1000.0000 unit/t
C03688/2 Negative speed 1000.0000 unit/t
C03691/1 Acceleration ramp 0.500 s
C03691/2 Deceleration ramp 0.500 s
C03691/3 Stop ramp 1.000 s
C03723 Master value with trimming - unit
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Start trimming C03058/15
C03026 Activate trimming C03058/16
FALSE Set trimming setpoint to 0 C03058/17