EDS94TA10040xxxx EN 1.1 - 10/2008 L 53
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Application error messages
4.13 Application error messages
For the output of application-specific error messages, an FB instance ApplicationError of
the function block L_DevApplErr is available.
r Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be activated by the
application.
r The first four inputs can be connected to the multiplexer parameters with the desired
tripping signals. The next four inputs are firmly connected to the tripping signals of the
application.
r Parameter setting: Tab All parameters
Error message Error ID Error response
1 Free (configurable via C03060/1) 8001 Error
2 Free (configurable via C03060/2) 8002 Error
3 Free (configurable via C03060/3) 8003 Error
4 Activate Modulo mode 8004 Warning
5 Following error 8005 Warning
6 Drive cannot follow 8006 No response
7 Drive system interrupted 8007 Quick stop by trouble
8 Reserved 8008 Warning
Parameter Lenze setting
C05900 Module ID 999
C05901/1...8 Error ID 1 ... 8 See table above
C05902/1...8 Error response 1 ... 8 See table above
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Application fault 1 C03060/1
FALSE Application fault 2 C03060/2
FALSE Application fault 3 C03060/3
Vue de la page 52