Lenze E94AxHE Technology Application Synchronism Manuel d'utilisateur Page 28

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 80
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 27
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Machine parameters
28 L EDS94TA10040xxxx EN 1.1 - 10/2008
Example of determining the machine parameters for the slave axis
O Tip!
The feed constant corresponds to the movement on the machine side when the
gearbox output shaft carries out one revolution (for selection as angle = 360°).
When the unit is set, the real unit of the machine for the selection of physical
values (e. g. speeds, accelerations and decelerations) is defined.
1. Set gearbox ratio for the motor in the form of a quotient
(numerator and denominator): i
2
= 12.612 = 12612/
1000
Numerator (C02520) = 12612
Denominator (C02521) = 1000
2. Set the same gearbox ratio for the position encoder:
Numerator (C02522) = 12612
Denominator (C02523) = 1000
3. Set feed constant (C02524).
For the conveyor drive: Vk = d
2
* π = 628,3185 mm
4. Set the selection "mm" as unit (C02525).
d
2
i
2
= 200 mm
= 12.612
Vue de la page 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 79 80

Commentaires sur ces manuels

Pas de commentaire