EDS94TA10040xxxx EN 1.1 - 10/2008 L 39
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
4.5.6 Mark synchronisation (setpoint)
[4-10] "Mark synchronisation" function in signal flow (schematic diagram)
This function serves to carry out a mark synchronisation of the setpoint via touch probe
sensor.
r Parameter setting: Tab Application parameters dialog level Synchronism Overview
Setpoint processing
r Configuration: Tab FB editor FB ToolControl
n Master value with trimming
o Actual value
M
v
Slave
Real master/
Virtual master
C03006 = 0
v
t
Dj
Dj Dj
TP TP
Note!
For this purpose, the touch probe sensor must be connected to the digital input
DI2!
Parameter Lenze setting
Value Unit
C03033 Tool synchronisation (TP) Deactivated
C03851 Positive TP limit 1.0000 unit
C03876 TP limit - hysteresis 0.0000 unit
Control inputs of the function Signal configuration
Lenze setting Control input (Multiplexer parameters)
FALSE Set TP position C03058/24