Lenze E94AxHE Technology Application CiA402 Device profi Manuel d'utilisateur Page 92

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 232
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 91
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
92 L EDS94TA11010xxxx EN 1.2 - 03/2010
Case 3: Axis already stands on reference switch:
1. Movement in negative direction with profile data set 2.
2. Negative edge of the reference switch activates touch probe detection.
3. The following positive edge of the encoder zero pulse/touch probe sensor sets the
reference (0x607C
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
CiA402 Homing method 08
Processes:
Case 1: Axis does not activate reference switch on the way to the limit switch:
1. Movement in positive direction with profile data set 1.
2. Reversing to positive travel range limit switch.
3. Positive edge of the reference switch activates profile data set 2.
4. Reversing with negative edge of reference switch.
5. Positive edge of the reference switch activates touch probe detection.
6. The following positive edge of the encoder zero pulse/touch probe sensor sets the
reference (0x607C
).
7. Absolute positioning to target position (C02643) with profile data set 2 (if 0x60FB/
7 ="0").
Touch probe/zero pulse
 Reference switch
 Positive travel range limit switch
1
3
2
0
1
2
Vue de la page 91