Lenze E94AxHE Technology Application CiA402 Device profi Manuel d'utilisateur Page 150

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 232
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 149
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Cyclic synchronous velocity mode (IEC 61800-7)
150 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.13.2 Object description
Objects described in other chapters:
Objects described in this chapter:
Index Name Data type Object type
Device control
0x6040 Control word UNSIGNED_16 VAR
0x6041 Status word UNSIGNED_16 VAR
Position control function
0x6064 Position actual value INTEGER_32 VAR
Interpolated position mode
0x60C2 Interpolation time period UNSIGNED_32 RECORD
Cyclic synchronous torque mode (IEC 61800-7)
0x6071 Target torque INTEGER_32 VAR
0x60B2
Torque offset INTEGER_32 VAR
0x6077 Torque actual value INTEGER_32 VAR
Grayed out = read access only
Index Name Data type Object type
0x606C Velocity actual value INTEGER_32 VAR
0x60B1
Offset velocity INTEGER_32 VAR
0x60FF
Target velocity INTEGER_32 VAR
Grayed out = read access only