Lenze E94AxHE Technology Application CiA402 Device profi Manuel d'utilisateur Page 154

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 232
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 153
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Cyclic synchronous velocity mode (IEC 61800-7)
154 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.13.6 Control commands & status information
The CiA402 (0x6040
) control word serves to execute control commands in the "cyclic
synchronous velocity mode":
The CiA402 status word (0x6041
) serves to output the following status information in the
"Cyclic synchronous velocity mode":
Control word Status Function
Bit 4 0 Reserved (bit must be set to "0")
Bit 5 0 Reserved (bit must be set to "0")
Bit 6 0 Reserved (bit must be set to "0")
Bit 8 0 Ê 1Stop
Status word Status Meaning
Bit 12 0 "Cyclic synchronous velocity mode" is not active
1 "Cyclic synchronous velocity mode" is active
Bit 13 0 Reserved (bit is always set to "0")