9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Torque limiting
172 L EDS94TA11010xxxx EN 1.2 - 03/2010
3.16 Torque limiting
Selecting the torque limits of the drive.
3.16.1 Input and output data
Input data
3.16.2 Object description
Objects described in other chapters:
Objects described in this chapter:
0x60E0 - Positive torque limit value
0x60E1 - Negative torque limit value
Index Name Data type Object type
0x60E0
Positive torque limit value UNSIGNED_16 VAR
0x60E1
Negative torque limit value UNSIGNED_16 VAR
Index Name Data type Object type
Cyclic synchronous torque mode (IEC 61800-7)
0x6072 Max torque UNSIGNED_16 VAR
Index Name Data type Object type
0x60E0
Positive torque limit value UNSIGNED_16 VAR
0x60E1
Negative torque limit value UNSIGNED_16 VAR
Index | Name:
0x60E0 | Positive torque limit value
Data type: INTEGER_32
Code: C03686
Positive torque limit
Scaling: 16384 100%
Setting range
(min. value | unit | max. value) Lenze setting
0 32767 16384
; Read access ; Write access CINH PLC-STOP ; PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x60E1 | Negative torque limit value
Data type: INTEGER_32
Code: C03687
Negative torque limit
Scaling: 16384 100%
Setting range
(min. value | unit | max. value) Lenze setting
0 32767 16384
; Read access ; Write access CINH PLC-STOP ; PDO_MAP_RX PDO_MAP_TX