Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014 83
Architecture: The ApplicationTemplate PackML in detail
Consistent data transfer
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
[9-31] According to the task configurations, the associated programs (CallFree, CallHigh, and CallMid) are to be called, which, in
turn, call the ModulAppCall programs (MAC_Task_Free, MAC_Task_High, and MAC_Task_Mid).
[9-32] The ModulAppCall program contains machine module applications which are assigned to the corresponding task.
The connection to the interface system (like for example the I/O system and visualization) is to
be carried out in the corresponding ModulAppCall program (MAC).
The module applications which are assigned to the corresponding tasks are stored...
...in the A70_MachineModuleSources folder or
...in the corresponding module libraries.
9.16 Consistent data transfer
A defined data area is exchanged between two tasks so that it is transferred consistently to the
other task.
Data consistency...
...is ensured depending on the data, or
In order to be able to use the multitasking
functionality in a machine module, the
machine module is provided with three
module applications (ModApp).