Lenze · Engineer · 2.13 EN - 10/2014 91
Establishing an online connection
Going online
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Name the controller according to the naming in the »Engineer« project:
9400 for 9400 HighLine
8400 for 8400 StateLine
3. Establish an Ethernet connection to the PROFIBUS-CPU
Load the »STEP 7« project into the CPU.
4. Integrate the PG/PC connection in the »STEP 7« project.
If there is no PG/PC connection, an error message appears in the »Engineer« ("Insert PG/
PC station").
5. Insert PG/PC station.
Menu command InsertStationPG/PC
6. Select interface.
Double-click on the inserted PC/PC station to display the properties.