Lenze · Engineer · 2.13 EN - 10/2014 247
Error messages
CAN generator
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Invalid value range for COB-ID (min and max inverted?) [NWCAN0019]
COB-ID beyond the limits. Generate new COB-ID for PDO [NWCAN0020]
COB-ID is used more than once [NWCAN0021]
COB-ID {0} outside the value range [NWCAN0028]
Response (Lenze setting printed in bold)
Error Warning Information
Cause Remedy
The data for the automatically allocated COB-ID range
are incorrect.
• Change to the Settings tab of the network specified.
• Set a range in the Automatically allocate identifier
group field supporting all devices connected to the
network.
• Set from < to.
Response (Lenze setting printed in bold)
Error Warning Information
Cause Remedy
During checking the COB-IDs it was observed that the
COB-ID of the process data object specified (associated
port) is beyond the COB-ID range defined under the
network settings. A new COB-ID is generated for the
process data object specified.
Ignore warning. In the case of time-critical processes,
however, the COB-IDs allocated in the CAN objects tab of
the network should be checked and possibly adjusted.
Response (Lenze setting printed in bold)
Error Warning Information
Cause Remedy
Generate new COB-ID for PDO
During checking the COB-IDs it was observed that the
COB-ID of the process data object specified (associated
port) has already been allocated. A new COB-ID is
generated for the process data object specified.
Ignore warning. In the case of time-critical processes,
however, the COB-IDs allocated in the CAN objects tab of
the network should be checked and possibly adjusted.
Response (Lenze setting printed in bold)
Error Warning Information
Cause Remedy
An attempt is made to transfer the COB-ID of the sender
to the receiver of project data objects. When this was
done, an error occurred. It is possible that the COB-ID is
outside the valid value range.
Check value range of the COB-ID.