Defining the system functionality
Parameter setting in the »Engineer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.6.5 Accepting parameter settings in the device
If you are connected to the device "online", you can accept the parameter settings stored in the
project to the device.
Going online
( 77)
How to accept parameter settings of the project in the device:
1. Select the parameter from the parameter list.
The symbol behind a parameter value indicates that the value in the device is different
to the parameter value stored in the project.
2. Click the icon in the Parameter toolbar to accept the selected parameter setting of the
project in the device.
8.6.6 Comparing parameter sets
This function serves to compare the parameter set of a device (parameter set A) to a parameter set
B.
The following parameter sets can be compared:
Online parameters of the device with offline parameter settings of the »Engineer« project
Online parameters of the device with the predefined default settings
Offline parameters of two devices.
How to carry out a parameter comparison:
1. Go to the Project view and select the device the parameter settings of which are to be
compared.
2. Select the Application data Compare parameter sets menu command or execute the
Compare parameter sets... menu command via the context menu of the device.
3. Go to the Compare Parameter Set dialog box and select the parameter sets to be compared
(Compare parameter set A and Compare parameter set B).