7.18 Pump
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.18 Pump
Pumps have the task to move a medium with a specific density against a stationary pressure. The
power (P) that has to be applied hydraulically for this purpose can be calculated by means of the
flow rate (Q).
The required data (efficiency, rated speed) of the pump can be gathered from the pump manu-
facturer's data sheet.
7.18.1 Calculations
For a pump according to the drawing the following applies:
[7-166] Equation 1: Power of the medium
The factor 3600 results from the adaptation of the units.
Power of the pump
Via the efficiency of the pump the required power of the pump is calculated:
[7-167] Equation 2: Power of the pump
P
ρ gQh
opr
⋅⋅
3600
---------------------------------- -
=
P
Pmp
P
η
Pmp
-------------
=