Lenze Drive Server Bus server S7 getting started Manuel d'utilisateur Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 63
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
Busserv er S7
L
107Busserver S7 DE/EN 1.0
6.3.7 FC94 (FC Process Data, 2 words, CP)
Function for process data access
The function FC94 can be used for both consistent and inconsistent process da ta transfer.
Parameters Data type Possible values/meaning
FirstDriveDW IN: INT Byte offset of the first drive da ta word in the data exchange
DB (decimal)
DriveSend_DB IN: BLOCK_DB Data exchange DB for send jobs to the external PROFIBUS
communication processor (CP)
DriveRecv_DB IN: BLOCK_DB Data exchange DB for read jobs from the external
PROFIBUS communication processor (CP)
Enable IN: BOOL
TRUE Drive enabled
E
n
a
b
l
e
I
N
:
B
O
O
L
FALSE Drive inhibited
QSP IN: BOOL
TRUE Quick stop (QSP) active
Q
S
P
I
N
:
B
O
O
L
FALSE Quick stop (QSP) not active
Reset IN: BOOL FALSEäTRUE TRIP reset executed
Setpoint1 IN: INT Setpoint process value (AIF-IN:W1)
ControlWord IN: WORD Control word according to DRIVECOM specification
Bit0 ... Bit4 are hidden and cannot be written.
RDY OUT: BOOL
TRUE Drive is ready for operation
O
U
O
O
FALSE Drive is not ready for opera tion
TRIP OUT: BOOL
TRUE Drive signals TRIP
O
U
O
O
FALSE Drive does not signal TRIP
ActualValue1 OUT: INT Actual process value (AIF-OUT:W1)
StatusWord OUT: WORD Status word according to DRIVECOM specification
Show/Hide Bookmarks
Vue de la page 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 62 63

Commentaires sur ces manuels

Pas de commentaire