Output parameters:
Global Drive Control (GDC) and DriveServer were used to l oad a complete parameter set.
An S7-315 (cycle time: 15 ms) and an S7-412 (cycle time: 2 ms) were used as PLC.
PROFIBUS was set to 1.5 Mbit/s.
Different interface modules were used.
MPI baud rate: 187.5 Kbaud
Baud rate of the serial i nterface for PC ada pter connection: 38.4 Kbaud
Transfer times detected for one parameter set:
PLC Interface module
Type Connection Controller PC-PLC connection Transfer time
S7-315
PROFIBUS on the CPU 82xx vector CP5511 (187.5 Kbaud) 44 s
S
7
3
1
5
CP342-5 82xx vector CP5511 (187.5 Kbaud) 54 s
PROFIBUS on the CPU 93xx CP5511 (187.5 Kbaud) 107 s
CP342-5 82xx vector 60 s 64 s
S7-412 PROFIBUS on the CPU
82xx vector (FIF) CP5511 12 s
S
7
4
1
2
P
R
O
F
I
B
U
S
o
n
t
h
e
C
P
U
82xx vector (AIF) CP5511 13 s
82xx vector (FIF) PC adapter 24 s
82xx vector (FIF) Ethernet 11 s
93xx CP5511 30 s
93xx PC adapter 56 s
93xx Ethernet 28 s
Summary:
The transfer time mainly depends on the cycle time of the PLC.
The longer the cycle time, the lower the influenc e of the bus rates.
A fast connection between PC and PLC accelerates data transfer. Yet, the cycle time remains
the limiting factor.
Some CPU cards permit the baud rate of the MPI bus to be set to up to 12 Mbit/s. If technology
allows, this increase in speed should be taken advantage of.
However, the PROFIBUS transfer rate only has a minor influence on the transfer time of a
parameter set.