9300 Servo PLC
Preface and general information
1−5
l
9300 Servo PLC EN 5.1
1.2.3 Access via system variables
You can use the system variables of a system block in your project after the system block has been
integrated into the control configuration of the DDS.
Open the input assistance in the DDS editors via <F2> to get a listing of all available system
variables:
This Manual lists the system variables in the table for the corresponding system block:
Variable Data type Signal type Address Display
code
Display
format
Note
DIGIN_bIn1_b
Bool Binary
%IX1.0.0 C0443/1
bin
... ... ...
DIGIN_bIn8_b %IX1.0.7 C0443/8
Example: Table with SB DIGITAL_IO inputs of the Drive PLC
1.2.4 Access via absolute addresses
System block inputs and outputs can also be accessed via absolute addresses according to the
IEC61131−3 standard:
For inputs use: For outputs use:
%IXa.b.c %QXa.b.c
a = node number
b = word address
c = bit address
This Manual lists the absolute addresses in the table for the corresponding system block:
Variable Data type Signal type Address Display
code
Display
format
Note
DIGIN_bIn1_b
Bool Binary
%IX1.0.0 C0443/1
bin
... ... ...
DIGIN_bIn8_b %IX1.0.7 C0443/8
Example: Table with SB DIGITAL_IO inputs of the Drive PLC