Lenze DDS Target 9300 Servo PLC V8.x Manuel d'utilisateur Page 102

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 169
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 101
2.14 STATEBUS_IO (node number 51)
9300 Servo PLC
System blocks
2−96
L
9300 Servo PLC EN 5.1
2.14 STATEBUS_IO (node number 51)
The state bus is a bus system specifically designed for Lenze controllers/PLCs.
This SB can set the state bus to LOW level and thus set all nodes connected to the state bus to a
previously selected status (e.g. TRIP, quick stop (QSP) or controller inhibit (CINH)).
The SB immediately detects when a node sets the state bus to LOW level and the corresponding
control signal can be processed in the PLC program.
STATEBUS_IO
ST
ST
1
STATE_BUS_bIn_b
C0441
STATE_BUS_bOut_b
X5
+10V
Fig. 2−30 STATEBUS_IO
Variable
Data type Signal type Address Display
code
Display
format
Note
STATEBUS_bOut_b Bool Binary %QX51.0.4 C0441 bin LOW signal output
STATEBUS_bIn_b Bool Binary %IX51.0.6 LOW signal detection
Every device connected to the state bus can set the state bus to LOW level (multi−master
operation).
A maximum of 20 devices (controllers/PLCs) can be networked via the state bus.
VU W ST 39 ST PE 28 A4PE
L2L1 L3 PE +UG -UG
9300 Servo PLC / 932X / 933X
VU W ST 39 ST PE 28 A4PE
L2L1 L3 PE +UG -UG
9300 Servo PLC / 932X / 933X
VU W ST 39 ST PE 28 A4PE
L2L1 L3 PE +UG -UG
9300 Servo PLC / 932X / 933X
Fig. 2−31 Networking via the state bus
Stop!
Do not connect an external voltage to terminals X5/ST!
Vue de la page 101