Lenze PLC Designer PLC-Designer (R2-x) SoftMotion Manuel d'utilisateur Page 191

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 290
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 190
L-force | PLC Designer - SoftMotion
The SM_CNC.lib library
SMC_GetMParameters
191 L DMS 5.2 EN 03/2011 TD17
7.10 SMC_GetMParameters
If the interpolator is currently on an M option, this program organisation unit can be used
to query the parameters that have been set for this M option (K, L, O).
Inputs (VAR_IN)
bEnable: BOOL
Program organisation unit is active if this input is set.
Inputs/outputs (VAR_IN_OUT) of the program organisation unit:
Interpolator: SMC_Interpolator
Interpolator instant
Outputs (VAR_OUT)
bMActive: BOOL (default: FALSE)
TRUE if an M option is currently pending.
dK, dL: LREAL (default: 0)
M parameters specified via words K and L
MParameters: SMC_M_PARAMETERS
M parameter that has been specified by means of the global data structure
gSMC_MParameters or by means of the variable transferred by O.
Vue de la page 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 289 290

Commentaires sur ces manuels

Pas de commentaire