DMS 1.0 EN - 07/2011 - TD05 L 17
Function library "LenzeIo1000Drv"
Function blocks
L_io1000ParAoDc - Parameterise analog outputs
4.3 L_io1000ParAoDc - Parameterise analog outputs
This FB serves to parameterise the analog output modules EPM-S500, EPM-S501, EPM-
S502 and EPM-S503.
A FALSE/TRUE edge at the bExecute input starts the parameter setting.
The dnState output shows the transmission status.
Inputs
Call possible in: ; Cyclic task
Interrupt task
; Time-controlled task (INTERVAL)
Event-controlled task (EVENT)
L_io1000ParAoDc
bExecute bDone
dwHandle dnState
byNodeAdr
byAnalogModuleNo
byNoOfChannels
bShortCircuitDetection_CH1
byFunction_CH1
bShortCircuitDetection_CH2
byFunction_CH2
bShortCircuitDetection_CH3
byFunction_CH3
bShortCircuitDetection_CH4
byFunction_CH4
Identifier/data type Information/possible settings
bExecute
BOOL
FALSEÊTRUE Start parameter setting of the analog output module
dwHandle
DWORD
9400 ServoPLC: Handle created by FB L_CanInit
Drive PLC, 9300 Servo PLC, ECS: 10
byNodeAdr
BYTE
1 ... 127 CAN node address of the I/O system
byAnalogModuleNo
BYTE
1 ... 64 Number of the analog output module
byNoOfChannels
BYTE
Number of channels of the I/O system
2 EPM-S500, EPM-S502
4 EPM-S501, EPM-S503
bShortCircuitDetection
_CH1 ... _CH4
BOOL
TRUE Activate short circuit detection channel 1 ... 4
byFunction_CH1 ... _CH4
BYTE
Function channel 1 ... 4
see system manual "I/O system 1000":
EPM-S500: Chapter 7.8.5
EPM-S501: Chapter 7.8.6
EPM-S502: Chapter 7.8.7
EPM-S503: Chapter 7.8.8