Function library
Positioning control
3.4.2 Machine parameters
3−26
l
EDSVS9332P−EXT DE 2.0
3.4.2 Machine parameters
Example
Purpose
l The physical unit (e.g.: mm, m, degrees) for a unit" is defined via the entry of the machine
parameters.
Function
l Entry of the gearbox ratio under C1202 and C1203, according to the nameplate data of the
gearbox.
C1202
C1203
5
Motor_speed
Getriebeabtriebsdrehzahl
l Entry of the feed constant under C1204. Enter the number of units (e.g.: mm) to be fed during
one revolution at the gearbox output side.
l Entry of the maximum motor speed (n
max
) under C0011. The limitation mainly applies to the
motor.
l Entry of the maximum speed (v
max
) under C1240. Limitation mainly applies to the entire
machine. It should be set lower than the speed that can be attained at maximum motor speed.
The maximum speed v
max
is considered as the reference for all speed data in the VTVEL
variable table.
v
max
v n
max
@
v
k
60 @ i
C1240 v C0011 @
C1204 @ C1203
60 @ C1202
l Entry of the maximum acceleration (a
max
) under C1250.
The maximum acceleration is considered as the reference for all acceleration data given in per
cent in the VTACC variable table.