Function library
Positioning control
3.4.13 Program sets (PS)
3−88
l
EDSVS9332P−EXT DE 2.0
3.4.13.11 Prg. fct. "Branch 1"
Purpose
Branching during program processing depending on the digital input signals (PFI).
Branching because of conditional query of two variables (<, >, = <=, >=):
1. Comparison of two variables with function block CMPPH" (7−109)
2. Connect the CMPPH output to the desired POS−PFI.
9300pos023
Fig. 3−37 Diagram − Branches 1 and 2
Function
l Selection of any PFI under C1325/x.
l Selection of the signal level under C1326/x.
l Selection of the PS to be branched to PS under C1327/x (if the PFI has the level selected).
l 32 PFO are available (see POS−PFO).
l GDC input: Programming" dialog
l Default setting: not active
3.4.13.12 Prg. fct. Branch 2"
Purpose
See branch 1
Function
l Selection of any PFI under C1334/x.
l Selection of the signal level under C1335/x.
l Selection of the PS to be branched to PS under C1336/x (if the PFI has the level selected).
l 32 PFO are available (see POS−PFO).
l GDC input: Programming" dialog
l Default setting: not active