Lenze E70ACxS Application Sample i700 (PLC Designer v3) Manuel d'utilisateur Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
Getting started - operating the Application Sample
Axis control during manual operation: manual control
26
Lenze · Servo Inverter i700 | Application Sample · DMS 1.0 EN - 09/2012 - TD11
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.5 Axis control during manual operation: manual control
How to proceed:
1. Click the AxisBasicControl button.
2. Select the desired axis: AxisX/AxisY/AxisZ.
3. Click the Internal Control button.
4. Acknowledge pending error by clicking the xResetError button.
5. Click the xRegulatorOn button.
6. Enable the controller: Click the xDriveStart button.
Now the controller has been enabled and can be controlled via the buttons.
Example: Click the xJoggingPos button to control the axis in positive direction of
rotation.