Function library
Function blocks
3.2.16 Comparator (CMP)
3−43
l
EDSVS9332S−EXT EN 2.0
CMP3
C0691
C0692
C0694/1
CMP3
CMP3-OUT
CMP3-IN1
C0694/2
CMP3-IN2
C0693/1
C0693/2
C0690
Fig. 3−38 Comparator (CMP3)
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CMP3−IN1 a C0694/1 dec [%] C0693/1 1 1000
CMP3−IN2 a C0694/2 dec [%] C0693/2 1 1000
CMP3−OUT a
Function
The description uses the example of CMP1 and also applies to CMP2 and CMP3.
The function of these function blocks can be set via code C0680 (CMP1). The following comparison
operations are available:
l CMP1−IN1 = CMP1−IN2
l CMP1−IN1 > CMP1−IN2
l CMP1−IN1 < CMP1−IN2
l |CMP1−IN1| = |CMP1−IN2|
l |CMP1−IN1| > |CMP1−IN2|
l |CMP1−IN1| < |CMP1−IN2|