Lenze EVS9332xS Manuel d'utilisateur Page 178

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 264
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 177
Function library
Function blocks
3.2.43 Motor potentiometer (MPOT)
3−126
l
EDSVS9332S−EXT EN 2.0
Tir
Tir
Tir
Tif
MPOT1−UP
MPOT1−DOWN
C0260
C0261
0
+
MPOT1−OUT
Fig. 3−108 Control signals of the motor potentiometer
In addition to the digital signals MPOT1−UP and MPOT1−DOWN another digital input exists
(MPOT1−INACT). The input MPOT1−INACT is used to activate or deactivate the motor potentiometer
function. Logic 1 at this input deactivates the motor potentiometer function. The input
MPOT1−INACT has priority over the inputs MPOT1−UP and MPOT1−DOWN.
When the motor potentiometer is deactivated, the motor potentiometer output (MPOT1−OUT)
follows the function set under C0264. The following functions can be set under C0264:
Vue de la page 177
1 2 ... 173 174 175 176 177 178 179 180 181 182 183 ... 263 264

Commentaires sur ces manuels

Pas de commentaire