EDS84DMOTPNET EN 2.0 - 11/2011 L 75
Communication manual 8400 motec PROFINET
Parameter reference
Parameters relevant for PROFINET communication
C13002
C13003
C13010
Parameter | Name:
C13002 | Gateway address
Data type: UNSIGNED_32
Index: 11573
d
= 2D35
h
Setting of the gateway address
Setting the IP configuration
( 30)
Setting range (min. value | unit | max. value) Lenze setting
0 4294967295 0
; Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13003 | Physical address
Data type: OCTET_STRING
Index: 11572
d
= 2D34
h
Display of the MAC-ID
Subcodes Info
C13003/1 MAC ID: Station
C13003/2 MAC ID: Port1
C13003/3 MAC ID: Port2
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13010 | Active IP address
Data type: UNSIGNED_8
Index: 11565
d
= 2D2D
h
Display of the active IP address
The active IP address may differ from the contents of code C13000
, depending on whether the station name was
changed via the fieldbus or the parameter.
Display area (min. value | unit | max. value)
0 255
Subcodes Info
C13010/1 Active IP address.1
C13010/2 Active IP address.2
C13010/3 Active IP address.3
C13010/4 Active IP address.4
; Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT